caldeiraria;leitura e interpretaÇÃo de desenho tÉcnico-senai/cst). arquivo Apostila Completa Desenho Tecnico Mecânico – Senai enviado para a disciplina . Apostila de Vapor · CPV Sistemas de principais métodos de aplicação de caldeiraria na tubulação CPM CALDEIRARIA Tubulação Industrial, SENAI CST. Apostilas Digitalizadas: 01 DVD Tempo Aproximado de Vídeo Aulas: 42 Horas e Dimensional: Régua, Trena e Paquímetro Traçado: Caldeiraria e Tubulação.

Author: Nall Tejind
Country: Guinea-Bissau
Language: English (Spanish)
Genre: History
Published (Last): 19 July 2004
Pages: 341
PDF File Size: 6.71 Mb
ePub File Size: 11.17 Mb
ISBN: 915-6-55693-946-4
Downloads: 87591
Price: Free* [*Free Regsitration Required]
Uploader: Faujas

The steam coils discharge condensate into a common condensate header pipe with one common steam trap for all three steam coils. Typical problems with group steam trapping: Locate the steam trap below the lowest 8. Install one stream trap for each steam heat transfer 2. Latent energy release and phase change which causes a reduction of occupied area.

Process Applications – Group Steam Trapping Practices Similar steam units unit heaters, tracers, steam coils, heat exchangers, etc. Each steam coil will have a different steam pressure drop from the steam inlet to the condensate outlet. The steam trap, sensing steam, will go into the closed position. Restriction of flow to the individual heat transfer unit, caused by internal restrictions, such as steam header pipe, tube diameter, or number of tubes.

  HABITANTE CARCOSA PDF

Freezing in cooler climates 5.

Boas práticas instalação de purgadores

One of the most important rules for steam trap 3. Check valves should be installed after the steam. This action will cause temperature fluctuation, water hammer and may cause freezing in colder climates. Temperature control problems 2.

Boas práticas instalação de purgadores

Install a visual indication of steam trap perfor- 6. The pressure drop results from:. In colder weather conditions, the steam coils can freeze and fail.

Three steam heated coils; the steam coils are separate units, or three separate sehai of one air heating system. The steam coil with the lowest pressure drop will allow steam to flow freely to the steam trap.

Steam in the discharge line from the steam coil with the lowest pressure drop will prevent proper condensate drainage, due to the steam pressure in the condensate drainage system. Martins, Damasceno, Awada – Pronto-socorro Pronto-socorro: Different fouling factors on the outside caodeiraria the heat transfer. Premature component failures a. The condensate, having only sensible energy, will reduce the steam coil performance and in some cases cause water hammer.

  MANIOBRA DE RITGEN PDF

Carbonic acid deterioration in the condensate drainage system. Air flow differences entering the steam coils. When steam condenses in the condensate drainage line the steam blanketing affect is released and condensate from all coils will be.

Assume that each steam coil is supplied with steam at the same pressure and that all the steam coils are the same size. COM allowed to drain. There are a few cases where grouping steam components to one steam trap is acceptable, but there are very few process applications where group steam trapping is acceptable.